THT CRYOGENICS

THT LIMITED

Tel.: 07770 395211
07986 837024
THT Cryogenics
THT CRYOGENICS

THT LIMITED

Tel.: 07770 395211
07986 837024

Carbon Dioxide Vessels Industrial Storage Systems
- Carbon Dioxide (CO2) Vessels - THT offer the following system specifications -

Vessel Data 6T 11T 16T 20T 25T 30T
Vessel Capacity (tons) 6.4 11.2 15.8 20.5 25.1 29.8
Available Liquid (tons) 6.0 10.5 14.9 19.3 23.6 28.0
Operating pressures Normal Working 20.7 bar
300 lbf/in²g
Maximum Design 24.1 bar
350 lbf/in²g
Pressure control limits in normal operation 20.0 - 21.0 bar
290 - 305 lbf/in²g
Insulation Thickness
Type
100mm
expanded foam
Refrigeration unit (for UK ambient to 27°C) Air cooled
R22 refrigeration
  Capacity (watts) 702 823 1057 1224 1498 1768
Electrical supply 400v. 3ph.
50Hz
Electrical consumption full load (amps) 2.8/ph. 3.7/ph. 5.3/ph.
Erection Weight (kg) 3050 5000 6250 7500 8250 9500
Nominal Weight full (kg) 9450 16200 22050 28000 33350 39300
Distance from fridge coil withdrawal (mm) 1500 2400
Vessel dimensions aLength overall (mm) 5170 5969 7771 9626 11405 13259
h Height overall (mm) 1934 2362
w Width overall (mm) 1830 2057
b Baseframe Length (mm) 4200 4673 6146 7593 N/A N/A
c Support centre of tressles (mm) 1850 2286 3429 4470 5563 6706
Tressle width (mm) N/A 400 400
Tressle length (mm) N/A 1798 1798
x Width over baseframe (mm) 1730 2000 N/A
Valve Type
2 Liquid filling
3 Vaporiser liquid
6 Vapour outlet and return
8 Vapour balance
10 3-way control for relief valves
11 Refrigeration control isolator
12 Gas to plant
vv bb
Homepage Cryogenic Systems Carbon Dioxide Vessels Gas Management Services Email Us 
THT Cryogenics, 22 Valley Road, Kirkella, East Yorkshire, HU10 7PG, England
Contact Telephone (UK) Number: 07770 395211 Fax (UK) Number: 01482 651859